GET A CONSULTATION -
/ Instrument Transformers
Precision Measurement. Reliable Protection.
Instrument transformers are essential components of modern high-voltage power systems, providing accurate current and voltage transformation for metering, protection and control applications.
The portfolio covers current transformers, inductive voltage transformers, capacitor voltage transformers, combined instrument transformers and solutions for gas-insulated applications across a broad range of high-voltage, extra-high-voltage and ultra-high-voltage systems. The technical catalogue covers instrument transformer solutions from 35 kV to 1000 kV, with individual product ranges extending higher depending on configuration.
/ Measurement You Can Rely On
Designed for Modern Power Systems
Instrument transformers provide the interface between the high-voltage primary system and secondary measuring and protection equipment.
Their role is to transform primary current or voltage into appropriate secondary values while providing electrical isolation from the high-voltage system. The available portfolio includes solutions for both measurement and protection duties.
Current Measurement
Current transformers provide secondary current signals for metering and protection applications.
Voltage Measurement
Inductive and capacitor voltage transformers convert high system voltage into suitable secondary values for measuring and protection equipment.
Protection
Dedicated protection accuracy classes and special-core configurations are available across the current transformer portfolio.
Combined Measurement
Combined instrument transformers integrate current and voltage transformer functions within one equipment configuration.
/ High-Voltage Performance
From Measurement to Ultra-High-Voltage Applications
The instrument transformer portfolio extends across a broad range of electrical requirements, from conventional high-voltage substations to EHV and UHV transmission systems.
Up to 1100 kV
Voltage Class
The general specification for capacitor voltage transformers extends to 1100 kV.
Up to 6,000 A
Rated Primary Current
Specified current transformer and combined transformer configurations provide rated primary current capability up to 6,000 A without primary interchange.
Up to 63 kA / 3 s
Short-Time Thermal Current
High-rating current transformer configurations provide short-time thermal current capability up to 63 kA for 3 seconds.
Up to 160 kA Peak
Dynamic Current
Dynamic current capability reaches 160 kA peak in specified current transformer configurations.
/ Accuracy for Measurement & Protection
Engineered Around Secondary Performance
Instrument transformer selection is not defined by voltage alone. Accuracy class, secondary ratings, protection requirements and system conditions must be considered together.
0.1 to 1.0 / 0.2S / 0.5S
Measurement Classes
These accuracy classes are represented across the documented current transformer range.
5P / 10P / 5PR / 10PR / PX
Protection Classes
Protection accuracy options are available according to the corresponding current transformer configuration.
TPS / TPX / TPY / TPZ
Special Core Classes
Special secondary core accuracy classes are represented in the current transformer portfolio.
0.2 / 0.5 / 3P / 6P
Voltage Transformer Classes
These accuracy classes are documented for inductive, capacitor and combined voltage transformer applications.
International Standards for Instrument Transformers. For this section I would again keep the website IEC-only, just as we did with bushings.
IEC 61869-1
IEC 61869-2
IEC 61869-3
IEC 61869-4
IEC 61869-5
ALIT CONSTRUCTION GROUP S.R.O.
WEB: www.alitcg.com
Address: Vršovické náměstí 111/2, 101 00 Prague 10, Czech Republic
ALIT CONSTRUCTION GROUP s.r.o. © 2026. All Rights Reserved. · IČO: 27335151 · Registered with the Municipal Court in Prague, Section C, File 268324 · Privacy Policy